The fans are designed for independent ventilation in deep mines. They may be used both for suction and delivery systems with an air pipe system inclination of up to 90 against the horizontal axis.

CERTIFICATION

The products are certified by the Physical Technical Testing Institute (PTTI) in Ostrava-Radvanice, notified body number 1026 in accordance with article 9 of the Council Directive 94/9/EC of March 23, 1994. The production quality system has been assessed according to EN 13980 and the products are certified by the Czech Mining Authority for use in mines in the Czech Republic.

The fans are designed in accordance with the Directive 94/9/EC ATEX and meet requirements set forth by the EN 13 463-1, EN 50 303:2000, EN13 463-1:2009, EN 13463-5:2003, EN 60079-0:2007, EN 60079 1:2009, EN 1710:2005.

NEW FEATURES

During air–drive operation of the combined fan the electric motor does not turn. This eliminates the voltage induction on the electric motor terminals. After the electric fan is switched off the motor is stopped, so generates no voltage, even if the fan wheel is actuated by the airflow in the air pipeline. The fan and connector designs are protected by the utility pattern registration.


VPAK

These fans may switch between the air and electric drives. The combined fan is automatically switched over to the compressed air drive mode in the event of power supply failure. The newly developed electromagnetic valve ensuring this switch-over has been certified separately by the PTTI Ostrava-Radvanice.

In any drive operation mode the fans may suck from environment IM1 (SNM3) during necessary time. If the fan is in the air drive operation mode it may also be placed in this environment, while the fan in the electric drive operation mode shall be placed in an IM2 (SNM2) environment.

VPAV

The air drive fans may be operated as device of group I category M1.


VPAE

For those fans with electric drive is the advantage of the possibility of suction of air mass with high methane content above 1.5%, for the shortest time. But it must be ensured that its surroundings are not an explosive mixture of air mass that content methane of over 1.5 %. In this case, the fan is turned off. In these cases it is necessary to use a ventilator VPAE-B, with the brake.

 
Fan Type inside
diameter
[mm]
Max.Air
volume delivered
Air/El.
consumpt.
Air
presure
Max.Pcv [Pa]
p=1,3
RPM Weight
VPAV-2-315 315 1,15 m3/s 120 m3/hod. 5 bar 650 3200 54 kg
VPAK-3-315 air drive
315 1,15 m3/s 120 m3/hod.
5 bar
650 3200 97 kg
VPAK-3-315 el. drive 315 0,95 m3/s 0,8 kW - 450 2820 97 kg
VPAE-B-3-315 - braked 315 0,95 m3/s 0,8 kW - 450 2820 90 kg
VPAE-N-3-315 - don´t braked 315 0,95 m3/s 0,8 kW - 450 2820 88 kg
VPAV-2-500 500 4,5 m3/s 437 m3/hod. 5 bar 1400 2700 176 kg
VPAV-2- 630 630 7,7 m3/s 685 m3/hod. 5 bar 1550 2500 279 kg
VPAK-3-630
air drive
630 7,7 m3/s 685 m3/hod. 5 bar 1550 2500 612 kg
VPAK-3-630 el. drive 630 8,5 m3/s 22 kW - 2200 2940 612 kg
VPAE-B-3-630 - braked 630 8,5 m3/s 22 kW
-
2200 2940 593 kg
VPAE-N-3-630 - don´t braked 630 8,5 m3/s 22 kW
-
2200 2940 583 kg
VPAK 855 air drive 800 7,5 m3/s 18 kW 4 bar 1100 1900 1060 kg
VPAK 855 el. drive 800 12 m3/s 55 kW - 3000 2960 1060 kg
VPAEP-N-2x2 855 - don´t braked 800 19,3 m3/s 2x55 kW - 6500 2960 1600 kg
VPAEP-B-2x2 855 - braked 800 19,3 m3/s 2x55 kW - 6500 2960 1660 kg
VPAE-B-855- braked 800 11 m3/s 55 kW - 3500 2960 850 kg
VPAE-N-855 -don´t braked 800 11 m3/s 55 kW - 3500 2960 820 kg